Project fails to start at boot with failed to start runtime
Status: open — upstream sbx runtime.
Symptom. On startup, a project is skipped with a warning and its sandbox
never comes up:
/project start or
/project restart fails the same way.
Cause. This is a bug in the sbx runtime, not in Celly. The runtime returns
a 500 Internal Server Error when the sandbox is woken, so the supervised
opencode serve child is never created. See the upstream report:
docker/sbx-releases#350.
Workaround. Restart the host. This is currently the only reliable recovery;
restarting Celly alone does not clear the stuck runtime.
Related
- Limitations — what the current release does not do.
- Operations — logs and project start/stop/restart.
- Roadmap — planned work.